CHEF

Platform / Equipment

Operations

Equipment

Know which cooler is drifting before the product does, and keep the repair on record.

Built Tested with simulated sensors

CHEF keeps a register of your coolers, freezers, cases, hot wells and other units, takes readings from whatever already measures them, and turns that into a plain status for each one. When something needs a technician, it opens the work order and keeps the service history. It has been built and tested with simulated sensors. It has not yet been run against real equipment.

Readings in, from whatever you have

A unit with a controller or a gateway beside it can send readings in. A unit with nothing connected gets a temperature typed in by the crew on the maintenance page.

  • Air, probe, evaporator and defrost temperatures
  • Compressor on and off, door open, device faults
  • Battery and signal strength for wireless sensors
  • The setpoint, shown as information only

A status you can act on

Every unit reads OK, WATCH, ALARM or OFFLINE. Each flag says "possible", shows the readings behind it, and is a prompt to go and look.

  • ALARM: out of range longer than the limit, a critical device fault, or a compressor that never stops
  • WATCH: a brief excursion, a rising trend, short-cycling, a door opened often or left open, low battery or weak signal
  • OFFLINE: nothing heard recently. A silent unit is never shown as OK.
A stainless-steel kitchen with ranges and ovens

Work orders and preventive maintenance

An alarm opens a work order with its evidence attached, one per problem. Preventive tasks open their own when due. Finishing a job writes the service history, which is append-only per unit.

  • Priority, assignee, vendor or tech, cost, parts and a photo link
  • Due and overdue maintenance tasks on a schedule you set
  • Any crew can open a work order; changes to equipment, ranges and keys need a manager on duty

Tied to your food-safety log

Link a cold unit to the HACCP cold-holding log and an excursion opens one entry asking the manager to inspect it and record what happened to the product. It stays open until someone does. CHEF decides nothing about the food.

On a real shift

How it works

1

The walk-in's readings show the air temperature rising for an hour. The unit goes to WATCH.

2

It stays out of range past the limit you set. The unit goes to ALARM, a work order opens with the readings attached, and the HACCP log gets an open entry.

3

The manager probes the product, records the corrective action, and assigns the work order to the refrigeration vendor.

4

The tech finishes the job, the order is marked done, and the visit is added to that unit's service history.

Make it yours

What you can change

Your units

Add each cooler, freezer, reach-in, display case, steam table, hot box, fryer, oven, dish machine or ice machine.

Ranges per unit

Replace the placeholder range for each unit with the values from your HACCP plan.

How long before offline

Set how long a unit can go without a reading before it shows OFFLINE, per unit.

Sensors and gateways

Register sensors and the gateways that hear them, and link each sensor to its unit.

Ingest keys

A manager mints keys per device, per gateway or for the whole site. Each is shown once and can be revoked.

Link to the HACCP log

Choose which cold units feed the HACCP cold-holding log when they have an excursion.

Preventive maintenance

Create recurring tasks with an interval in days. Each due date opens a work order.

Built in

Rules CHEF holds to

Read-only and inbound only

CHEF only receives readings. It never connects to a controller, never sends a command and never writes a setpoint. A test checks the module has no outbound call.

No brand or protocol claimed

Two example adapters show the format. A real one is built once we know what your controllers actually send, or a small bridge on your side sends the standard format.

Placeholder limits are labelled

Default ranges and thresholds are marked as placeholders on screen until your HACCP plan's values replace them.

Bad clocks cannot fake health

A reading stamped far in the future or more than a day old is kept but ignored for status. A device with a wrong clock reads OFFLINE.

Defrost does not count

Readings taken during defrost never start or end an excursion.

Coming

  • Adapters for real controllers and sensors, built once a kitchen's actual equipment is known
  • Tuned thresholds from a first real install
See it working

Try CHEF in your browser

The demo runs on sample data, with nothing to install. Or write to [email protected] and tell us how your kitchen runs.